Year |
Make |
Model |
Condition |
Price |
Details |
|
Ad # 6560 | Autoclaves / Sterilizing Chambers |
1974 |
Turbo Macine Company |
FS-1200 |
Good |
sold |
Photo /
More Info. |
66" x 150", 55 psi, 305F Turbo Machine Autoclave: Max Working Pressure: 55 psi
Max Working Temp: 305F
National Board #: 1015-00
Dia" 66"
Length: 12" 6" |
|
Ad # 6559 | Autoclaves / Sterilizing Chambers |
Nov 70 |
Turbo Machine Company |
FS-1200 |
Good |
sold |
Photo /
More Info. |
66" x 150", 55 psi, 305F Turbo Machine, Autoclave: National Board # 8323
Max Design Pressure: 55 & FV psi @ 305 F
Max. Design Temperature: 305 F & 55 & FV psi
Inspection Ins. EC in
Shell: 312 in
Head: 312 in
Radius of Diam: 66"
Length: 150" |
|
Ad # 14638 | Autoclaves / Sterilizing Chambers |
2006 |
Boiler Miura |
LX-200-05 |
Good |
sold |
Photo /
More Info. |
200 HP: Boiler Miura LX-200-05
200hp capacity
Max. working pressure: 170 Psig
Heating surface area: 397 Sq Ft
Design temperature: 400 °F
Max. steaming capacity: 6900 Lb/Hr
Max. Input: 7900 x 1000 BTU/Hr
Min. Input: 2500 x 1000 BTU/Hr
Fuel type (Gas): Propane
Fan motor: 3 Phase / 460 V / 60 Hz |
|
Ad # 5823 | Autoclaves / Sterilizing Chambers |
|
THERMAL EQUIPMENT |
36 x 92 HYDROCLAVE |
Very Good |
Sold |
Photo /
More Info. |
THERMAL EQUIPMENT Hydroclave, 36" Diameter x 192" Long, 3000 PSI Water: THERMAL EQUIPMENT Hydroclave, 36" Diameter x 192" Long, 3000 PSI Water Pres... |
|
Ad # 5822 | Autoclaves / Sterilizing Chambers |
1989 |
Thermal Equipment |
Thermal Equipment 19 x 39 |
Very Good |
Sold |
Photo /
More Info. |
18¾" Diameter x 39" Long Composite Bonding Autoclave: National Board# 204, Job# 8942,
Inside Dimensions 18¾" Diameter x 39" Long
Maximum Capacity 13" x 13" x 36"
Maximum Pressure 325 PSI @ 650°F
Working Capacity 315 PSI @ 800°F
Shell Thickness 3/8"
Overall Dimensions 108" x 72" x 96" High
Equipped with: Electric Heating w/ Fan
Water Cooled (No cooling tower supplied)
HP386 Computer w/ Printer
Chart Recorder
Vacuum Pump
(4) Sensor Ports
Hinged, Bolt Up Door
|
|
Ad # 14973 | Autoclaves / Sterilizing Chambers |
2006 |
|
LX-100 |
Good |
sold |
Photo /
More Info. |
: Brand: MIURA
Models: LX-100
Serial Number: 45S451758
Qty: 1
Power: 100
Phases: 3
Year: 2006
Other characteristics: 170 PSI, 400 F,
MANUFACTURED BY: MIURA BOILER CO, MADE IN
CANADA. |
|
Ad # 14974 | Autoclaves / Sterilizing Chambers |
1997 |
|
CB1200500200 |
Good |
sold |
Photo /
More Info. |
30 TON: Brand: Cleaver Brooks
Models: CB1200500200
Serial Number: 0L097092
Qty: 1
Voltage: 230
Phases: 3
Year: 1997
Shipping dimensions: L 18 ft 6'' x W 9 ft x H
11 ft
Other characteristics: Oil pump motor 11 v,
Made in Wisconsin USA
Max pressure 200 st PSI, INPUT 20.411.600,
BTU/HR NAT, Gas 145.8 GPH Oil, 230 v, 3 ph, 60
Hz, 78.5 amp, Minimum circuit ampacity 92.5
amp, Max. Rating of circuit protection 314 amp,
Blower motor 20 hp, Air compressor motor 7.5
hp, Year 1997.
|
|
Ad # 14975 | Autoclaves / Sterilizing Chambers |
1993 |
|
CB 600-500 |
Good |
sold |
Photo /
More Info. |
30 ton: Brand: Cleaver Brooks
Models: CB 600-500
Serial Number: L-91968
Qty: 1
Voltage: 460
Phases: 3
Year: 1993
Other characteristics: Control Circuit 120v, 1
hp, 40 hz, 7 amp. OIL PUMP MOTOR 100 v.
Max pressure 150 psi, INPUT: 20.922.000, Gas
139.50 ph oil, minimum circuit ampacity 94 amp,
all compressor motor 5 hp, Oil heater 7.5 hp,
460 v, 3 ph, 39 amp, 60 hz,year 05/10/93. |
|
Ad # 14972 | Autoclaves / Sterilizing Chambers |
2008 |
|
LX-200-05 |
Good |
sold |
Photo /
More Info. |
: Brand: MIURA
Models: LX-200-05
Serial Number: 475461933
Qty: 1
Voltage: 200
Phases: 3
Year: 2008
Other characteristics: 400 °F, 170 PSI, GAS